Launch offer — valid today only

📄 Digital book in PDF · read it on your phone or print it

The Refrigerant Licence and Split Systems in Drawings Read the Gauges and Run Every Procedure in the Same Order

The refrigerant cycle, safety classes, the gauge manifold, recovery, the nitrogen pressure test, evacuation, the decay test, charging and faults on the gauges. Each topic has its own page: the drawing first, then what you need to remember. 71 illustrated pages.

START STUDYING THIS WAY

🔒 Secure checkout · PDF by email · 30-day guarantee

Every topic, its own pageEach procedure drawn, with the explanation alongside
71 illustrated pages8 parts, from the cycle in 4 parts to the on-site checklist
Up-to-date sourcesThe Ozone Protection and Synthetic Greenhouse Gas Management Act and Regulations, the Refrigerant Handling Code of Practice and AS/NZS 5149
PDF by emailFormat

Look Inside the Book

Every page has one big drawing and a box with the numbers and steps you need to know:

Compressor → condenser → expansion → evaporator: high side red, low side blue.
Compressor → condenser → expansion → evaporator: high side red, low side blue.
A = exposure limit ≥ 400 ppm; 1 no flame, 2L slow-burning, 3 highly flammable.
A = exposure limit ≥ 400 ppm; 1 no flame, 2L slow-burning, 3 highly flammable.
Blue = low side, red = high side, yellow = service hose, and the °C ring is saturation.
Blue = low side, red = high side, yellow = service hose, and the °C ring is saturation.
Cores out, short hoses, gauge at the system, under 500 microns, isolate, hold 60 minutes.
Cores out, short hoses, gauge at the system, under 500 microns, isolate, hold 60 minutes.
60-minute hold: under 600 microns and less than 100 microns of rise
60-minute hold: under 600 microns and less than 100 microns of rise
Extra metres × grams per metre from the manual = what goes on the scale
Extra metres × grams per metre from the manual = what goes on the scale
Low side, high side, superheat and subcooling for 5 faults, on one page
Low side, high side, superheat and subcooling for 5 faults, on one page
Superheat, subcooling, absolute pressure and extra charge: four formulas, four worked examples
Superheat, subcooling, absolute pressure and extra charge: four formulas, four worked examples

Swipe to see more →

These are real pages from the book. The table of contents is the full one: 8 parts and 67 topics.

The Problem Isn't You. It's How It Was Explained.

You're on site with the gauge manifold hooked up. Your supervisor asks what the low side is telling you, and the needles, the hoses and that ring of °C numbers all blur together.

You've read the chapter. But the course notes explain the manifold in paragraphs: which hose goes where, which valve opens what, gauge pressure against saturation. Nothing on the page looks like the tool in your hands.

Blue = low side, red = high side, yellow = service hose, and the °C ring is saturation.

In this book the manifold is one page: blue for the low side, red for the high side, yellow for the service hose, and the °C ring labelled for what it is: saturation temperature. One drawing, read in ten seconds.

Safety classes, evacuation in 6 steps, the decay test, charging by weight: each one has its own page, drawn the same way.

You look at the gauges, you know what they're saying and you get on with the job, without going back to the notes.

COMPARE FOR YOURSELF

The Same Topic, Two Ways to Study It

THIS
  • The manual: line after line
  • Safety classes explained only in words
  • You turn up to the assessment unsure
Refrigerants are assigned a safety classification comprising an upper-case letter denoting toxicity and a numeral denoting flammability. Class A refrigerants have an occupational exposure limit of not less than 400 ppm, whereas Class B refrigerants have a limit below that value. Flammability is designated as Class 1, indicating no flame propagation under the specified test conditions; Class 2L, indicating lower flammability with a maximum burning velocity not exceeding 10 cm/s; Class 2; and Class 3, indicating higher flammability, with corresponding implications for charge limits, ventilation and installation requirements.
FOR THIS
  • A1, A2L and A3 in one drawing
  • The letters and limits in a box
  • You see it and it makes sense
A = exposure limit ≥ 400 ppm; 1 no flame, 2L slow-burning, 3 highly flammable.
CONTENTS

Take a Look at the 8 Parts and 67 Topics

The cycle in 4 parts, refrigerants and safety, the law and your licence, your tools, installing a split, the 4 procedures in order, reading faults on the gauges and the on-site checklist: 71 pages, all illustrated.

IThe cycle in 4 parts · pp. 5-14
  1. Heat only moves from hot to cold
  2. The circuit: 4 parts, always in the same order
  3. The compressor: the pump of the system
  4. The condenser: where the heat leaves
  5. The expansion device: the pressure drop
  6. The evaporator: where the heat comes in
  7. Pressure and temperature move together
  8. Gauge pressure vs absolute pressure
  9. Superheat and subcooling in one picture
  10. Heat pump mode: the reversing valve
IIRefrigerants and safety · pp. 15-21
  1. Ozone and global warming: ODP and GWP
  2. The refrigerants you'll meet on the job
  3. Safety classes: A1, A2L, A3
  4. Working with A2L gas like R32
  5. Blends and temperature glide
  6. Cylinders: refrigerant vs recovery
  7. PPE and the 3 real risks
IIIThe law and your licence · pp. 22-27
  1. Why venting is an offence
  2. Licence types at a glance
  3. Licence vs trading authorisation
  4. Electrical work: where your licence stops
  5. Records you must keep
  6. Returning recovered refrigerant
IVYour tools · pp. 28-35
  1. The gauge manifold, read in 10 seconds
  2. Hoses, valves and low-loss fittings
  3. Vacuum pump and micron gauge
  4. The recovery machine
  5. The charging scale
  6. Leak detectors: 4 ways to find a leak
  7. Nitrogen cylinder and regulator
  8. Pipe tools: cutter, bender, flaring tool
VInstalling a split · pp. 36-43
  1. Siting the indoor unit
  2. Siting the outdoor unit
  3. Pipe size and pipe length
  4. Bending copper without kinks
  5. Flaring in 5 steps
  6. Torque: tight enough, not too tight
  7. Brazing with a nitrogen purge
  8. Condensate drain and insulation
VIThe 4 procedures, always in order · pp. 44-57
  1. The order that never changes
  2. Pump-down into the outdoor unit
  3. Recovery: vapour method step by step
  4. Recovery: liquid push-pull
  5. Pressure test with dry nitrogen
  6. The standing test: reading the drop
  7. Evacuation: why microns
  8. Evacuation in 6 steps
  9. The decay test: what the micron gauge tells you
  10. Triple evacuation
  11. Charging by weight
  12. Charging by superheat
  13. Charging by subcooling
  14. Liquid or vapour when charging?
VIIReading faults on the gauges · pp. 58-64
  1. The 5 gauge patterns
  2. Low charge
  3. Overcharge
  4. Restriction
  5. Airflow problems: dirty filter or coil
  6. Non-condensables in the system
  7. Decommissioning a split
VIIIReview and on-site checklist · pp. 65-71
  1. Units card: kPa, bar, psi, microns, °C
  2. Formulas card
  3. Job checklist: install
  4. Job checklist: service and repair
  5. The most frequent mistakes
  6. What the assessment usually asks
  7. Glossary in plain words

One Page, One Topic, All Clear

Think of it this way:

You've pulled a vacuum on a new split, the pump's isolated, and you need to know whether that system is dry and tight before you open the service valves.

You turn to the decay test page and there it is: the 60-minute hold drawn next to the micron gauge, under 600 microns and less than 100 microns of rise, in one box.

60-minute hold: under 600 microns and less than 100 microns of rise

Same with flaring, brazing with a nitrogen purge, charging by superheat or subcooling, safety classes and the 5 gauge patterns: each one on its own page.

Refrigeration & Aircon Illustrated is 8 parts and 67 topics, all drawn, and it finishes with units and formulas cards, install and service checklists and a glossary in plain words.

What you see drawn, you don't have to memorize.

What's Inside Refrigeration & Aircon Illustrated:

Ipp. 5-14

The cycle in 4 parts

Heat moving from hot to cold, the 4-part circuit, compressor, condenser, expansion device, evaporator, pressure and temperature, gauge vs absolute, superheat and subcooling, the reversing valve.

IIpp. 15-21

Refrigerants and safety

ODP and GWP, the refrigerants you'll meet, safety classes A1, A2L and A3, working with A2L gas, blends and glide, cylinders, PPE and the 3 real risks.

IIIpp. 22-27

The law and your licence

Why venting is an offence, licence types, licence vs trading authorisation, where electrical work starts, records to keep and returning recovered gas.

IVpp. 28-35

Your tools

The gauge manifold, hoses and low-loss fittings, vacuum pump and micron gauge, recovery machine, charging scale, leak detectors, nitrogen and regulator, pipe tools.

Vpp. 36-43

Installing a split

Siting the indoor and outdoor units, pipe size and length, bending copper, flaring in 5 steps, torque, brazing with a nitrogen purge, drain and insulation.

VIpp. 44-57

The 4 procedures, always in order

The 4 procedures in the order you'll do them on site, so the steps never swap places: pump-down, vapour and liquid recovery, nitrogen pressure test, standing test, evacuation in 6 steps, decay test, triple evacuation and the 3 ways to charge.

VIIpp. 58-64

Reading faults on the gauges

From the needles to the fault: the 5 gauge patterns, low charge, overcharge, restriction, airflow problems, non-condensables, and decommissioning a split.

VIIIpp. 65-71

Review and on-site checklist

Units card, formulas card, install and service checklists, the most frequent mistakes, what the assessment usually asks and a plain-words glossary.

At the end of the book: Units and formulas cards, install and service checklists, the most frequent mistakes and a plain-words glossary.

Plus: 2 Free Books

Licence Practice Questions with Answers

BONUS 1: «Licence Practice Questions with Answers»

Value on its own: US$ 17.90

Test yourself on the cycle, safety classes, recovery and charging with exam-style questions, each answer explained in one or two lines.

15 Common Mistakes, Before & After

BONUS 2: «15 Common Mistakes, Before & After»

Value on its own: US$ 14.90

See the slips techs make most often, from skipping the nitrogen purge to breaking vacuum too early, each drawn wrong and then right.

Refrigeration & Aircon Illustrated with 2 Free Books

  • Refrigeration & Aircon Illustrated: 71 illustrated pagesUS$ 63
  • BONUS 1: Licence Practice Questions with AnswersUS$ 17.90
  • BONUS 2: 15 Common Mistakes, Before & AfterUS$ 14.90
  • High-resolution PDF to printIncluded
Total value US$ 95.80
YOUR PRICE:
US$ 27
You save US$ 68.80
YES, I WANT REFRIGERATION & AIRCON ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

Secure purchaseEncrypted payment30-day guarantee

PDF by email: We email you Refrigeration & Aircon Illustrated as a PDF, together with the two free books. It's a single payment: no installments, no extra charges.

Who This Book Is For

You're doing your Cert III

You're doing your Cert III

Back to study after years away, you get the cycle and every procedure as a drawing, always in the same order, so the theory has something to hang on.

You're a sparky adding split systems

You're a sparky adding split systems

You know the electrical side. The book gives you the refrigerant side in order: recovery, nitrogen test, evacuation and charging, then the practice questions bonus book before your licence assessment.

You already install splits

You already install splits

You keep it printed in the ute: the decay test, the 5 gauge patterns and the formulas card, right there when you need them.

Everything You Get Today

US$ 95.80US$ 27
YES, I WANT REFRIGERATION & AIRCON ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

30DAYS
GUARANTEE

30-Day Guarantee

Try Refrigeration & Aircon Illustrated for 30 days, bonus books included.

We refund everything if the file won't open, if the book isn't what you see here, if you were charged twice or if the email doesn't arrive. Just email us.

You pay once. No subscriptions.

Frequently Asked Questions

Is it for me if I already do the work and need the licence?

Yes. It isn't a beginner's book with the basics padded out: it puts what you already do in a fixed order, with the numbers in kPa, °C and microns, so you can explain it as well as do it. It covers split systems and the procedures behind the refrigerant handling licence; the licence types are explained in Part 3.

Where does the content come from?

It's checked against Australian sources: the Ozone Protection and Synthetic Greenhouse Gas Management Act and Regulations, the licensing rules of the Australian Refrigeration Council, the Refrigerant Handling Code of Practice and AS/NZS 5149. Metric units throughout, no psi or °F.

Is it official material?

No. It's independent illustrated study material. It isn't issued, approved or endorsed by any council, regulator or standards body.

Does it replace the course or my training?

No. The licence comes from your qualification and the application to the licensing body. The book helps you study and revise; it doesn't replace supervised training or the manufacturer's instructions.

Are the practice questions the ones from the assessment?

No. They're written for this book, in the style of the topics that are asked most, with each answer explained in a line or two.

When and how does it arrive?

As a PDF by email, to the address you enter at checkout. The 2 bonus books come the same way.

Do I have to pay every month?

No. It's a one-off payment. No subscription.

Can I have it on paper?

It isn't posted as a printed book: you get a PDF by email, made to print. Print the whole book or just the pages you want to keep in the ute.

How does the refund work?

You have 30 days. We refund everything if the file won't open, if the book isn't what you see on this page, if you were charged twice or if the email doesn't arrive: just email us.

Before You Close This Page

No more rereading notes that don't stick.

The gauge manifold: you see it drawn and that's it.

You turn up to the assessment knowing where everything is.

Drawings make studying faster.

The book is right below.

One-time payment: US$ 27 · Guarantee: 30 days · PDF by email

YES, I WANT REFRIGERATION & AIRCON ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.